Thermal Simulation of Custom Designed House to Test Application of new Cooling methods
Abstract
A traditional Iraqi house used to be compatible with climate and allows the users to
live in a genealogically comfortable way in winter and summer. And because of the evolution Of technology and contemporary housing demands, this kind of housing became inappropriate
that led to the appearance of a new Iraqi house design which offers overall comfortable living but it cause a terrible loss of power for heating and cooling. Several new methods have been tested in the University of Technology in Baghdad to cool the building interior through cooling the structural envelope. The tests have been done on a test room that treated with some environmental solutions depending on evaporative cooling which consumes a less power then other cooling technologies. the results have been compared.
The solutions included using a cooled roof by(roof pond) plus evaporative cooler that
cools the air over the roof pond and through a cavity wall. this particular research
concentrates on experimenting the best tested solutions on an experimental modern house
with 250 m ,4 bed rooms,2 bath rooms and court with internal garden covered with sun
breakers. The house was supplied with water pond on roof, cavity walls cooled by evaporative air cooler and windows with double glazing to increase thermal insulation. The cooled air that came from both the roof and the wall flows into the court and goes out from the top. The results have been simulated by using Ecotect vs. 2 computer program and it seems that this system would reduce the cooling load for such a house by 78% if cooled using conipressor air conditioners to a temperature of(ordinary house). And 53% to reduce heat temp. less than 26 degree. The results also shows that most of the power savings happens in the 2nd floor becauseof the roof pond. This design also saves about 39% of the heating power in winter because of the air cavity in the roof and walls.
Downloads
You are free to use the work, but you have to attribute (refer to) the work in the manner specified by the author or licensor (but not in any way that suggests that they endorse you or your use of the work).
IRAQI J. ARCHIT & PLANN grants you the right to publish the metadata of the journal, it's issues and articles under the terms of the Creative Commons Attribution-ShareAlike 4.0 International License.
Author(s) hold the copyright of their aricles without restrictions. However, IRAQI J. ARCHIT & PLANN holds publishing rights for articles and their revisions once the article is published.
Authors can archive pre-prints (ie pre-refereeing) and post-prints (i.e. final draft post-refereeing) versions of the work they submitted to IRAQI J. ARCHIT & PLANN using non-for-profit open-access servers whether on author's personal website and/or institutional repositories including the university or research center where the author work.. For post-prints, only the IRAQI J. ARCHIT & PLANN’s as-published PDF version is permitted and the published source (IRAQI J. ARCHIT & PLANN’s website) must be clearly acknowledged within the archiving webpage.